Biomarker Profiling

Nuclear Magnetic Resonance Spectroscopy is an important technique for the analysis of biological fluids in life science applications such as metabonomics, metabolite identification, biomarker analysis etc. Flow-NMR techniques are ideal in these applications for high-throughput screening and hyphenation with other analytical methodologies such as chromatography and mass spectrometry. Enhanced mass sensitivity, superior fluidic performance, reduced cost, and greater speed are possible using capillary-scale, microflow NMR due to the reduced sample and solvent volumes required, enabling analysis of fluids from smaller animals or any fluid that is only available in small volumes.

More Information

Biomarker Profile

Featured Chapter

Chapter 16.  NMR-Based Metabolomics for Biomarker Discovery

Biomarker Methods in Drug Discovery and Development, Edited by Feng Wang, Humana Press

Narasimhamurthy Shanaiah PhD, Shucha Zhang MS, M. Aruni Desilva MS, Daniel Raftery PhD

Summary

Metabolomics provides a powerful set of tools for pharmaceutical and clinical research in a number of important areas that include drug development, early disease detection, patient stratification for treatment, and information on disease processes. With its ability to discover new metabolic markers, metabolomics (as well as metabolic profiling and metabonomics) is highly effective for drug development by providing early preclinical indications of efficacy and toxicity. The most information-rich techniques currently employed in metabolomics-based studies today are nuclear magnetic resonance (NMR) spectroscopy and mass spectrometry (MS). NMR spectra of untreated biosamples provide an overview of all metabolites present, and the complete spectrum can be used as a fingerprint of metabolic status. Analysis by multivariate statistical methods is used to identify potential biomarkers of altered metabolism that can improve the understanding of the health and disease processes. Current trends and recent advances in NMR-based metabolomics are focused on the development of advanced NMR methods, improved multivariate statistical data analysis, and a number of efforts to identify altered metabolites and pathways. Applications in the areas of toxicology, inborn errors of metabolism, cardiovascular disease, and cancer detection are described, and the prospects and the future directions of the technology are highlighted.

Excerpt

The main alternative to MS-based approaches to metabolic profiling is provided by NMR. NMR spectroscopy is especially suitable for metabolomics as it requires little or no sample preparation; is rapid, nondestructive, and noninvasive; and provides highly reproducible results.  These features can provide important advantages in a number of situations. NMR spectroscopy typically have lower sensitivity compared with MS methodologies. However, with the introduction of higher field magnets (up to 900 MHz), cryogenically cooled probes (that reduce  thermal noise), and microprobes equipped to handle very small (high nanoliter to low microliter) samples, methodologies that couple NMR to liquid chromatography and solid-phase extraction (19,20), sensitivity and resolution are being improved. More recently, high-resolution magic-angle spinning NMR techniques have created opportunities for the application of metabolomics to intact tissue samples (21).

Typically, 1H NMR spectra of biofluids such as urine and plasma contain thousands of signals arising from hundreds of endogenous molecules representing many biochemical pathways. Conventional measurements of the major NMR signals can be used to detect biochemical changes,  but the complexity of the spectra and the presence of natural biological variation across a set of samples make the use of data reduction and pattern recognition techniques highly advantageous. The use of statistical tools such as principal component analysis (PCA), hierarchical cluster  analysis (HCA), stepwise linear regression (SLR), and partial least squares (PLS) in the interpretation of metabolic profiling data set is now widespread (7,22). These methodologies are extremely helpful tools for filtering the large amounts of data and for accessing the often-subtle biochemical perturbations latent in the spectra. In addition, these approaches are used to extract single biomarkers or sets of biomarkers with the best properties for the prediction of diseases, organ function, or drug toxicity and efficacy.

New Downloads

Featured Speaker

Dr. Tom O’Connell, Hamner-UNC-Metabalomics Laboratory

Our Customer Partner

CapNMR + One-Minute NMR

Hamner_Sign

Need More Results?

Automate to your existing cryoprobe with One-Minute NMR.

Run NMR on your LC-MS Fractions!  Get all the information!

Note

Concentrate metabolites with SPE-NMR!

Biomarker Profiling

BU-CMLD Loads 54-Vial Tray

Open-Access NMR

OLD WAY

“The walk-up spectrometers are accounted in 10-minute increments and can be used reserved for blocks of time ranging from 10 minutes to 24 hours depending on the time of day and whether the usage is on a weekend or weekday. To gain access to these instruments, please Request a xxxx CIC Account. After we have evaluated your needs, CIC staff will create your accounts and schedule training sessions as appropriate.”

NEW WAY

  1. Log in your sample from any browser, tablet or smartphone.
  2. Bring the sample to the NMR system and place it in the reserved tray location.
  3.  Click the Run button. Walk away.  Your results will be waiting in your Inbox.

LEAP-GNF-001

SMASH 2012

Protasis hosted a table at this year’s Small Molecule NMR (SMASH) Conference on September 9-12 in Providence, RI. We set up a One-Minute NMR system and ran it through its sample loading paces. The conference was held jointly with CoSMoS, the Society for Small Molecule Science with about 300 total attendees. Protasis showed two joint posters with our customer collaborators on CryoFlow NMR:

Poster #49
Improvements in Flow-Injection NMR as a Tool for High-Throughput Sample Analysis
Paul Krolikowski (1), L. Steven Hollis(1), Roger Kautz (2) and David Strand (3)

1.  Molecular Structure, Amgen Inc., Cambridge, MA, USA
2.  Barnett Institute at Northeastern University, Boston, MA, USA
3.  Protasis Corporation, Marlboro, MA, USA

Recently, dramatic improvements in S/N have been obtained using customized flow-NMR instrumentation by incorporating a small volume flow-cell (10-60 uL) with a high-sensitivity 600 MHz Bruker 5-mm TCI-cryoprobe and a Protasis sample delivery system. The large sensitivity gain provided by cryoprobe technology (as much as 20X increase compared to a micro-coil 500 MHz RT flow-probe) has dramatically reduced data collection times to a point where routine 1H and g-HSQCdept spectra can be collected on small samples (25 uL at 20 mM) in under 10 minutes. These hardware improvements have allowed implementation of rapid quantitative-NMR analysis for HTPP (High Throughput Purification Process) samples using Digital-Eretic referencing as an integral calibration technique. In addition, new flow-cell inserts have been designed which easily can be interchanged to alter sample volume or switched from flow to tube based operations in just a few minutes with minimal setup time.
The concept of tailoring the flow-cell volume to match that of the intended sample stream (with an active volume of 10, 30 or 60 uL) using a standard Bruker pass-through cryoprobe, will be discussed as part of our continuing effort to improve NMR sampling efficiency. The Protasis sample delivery station and operating system (One-Minute NMR) provides a flexible and convenient platform for submitting samples in 96-well plate format, or as single samples in walk-up mode. Automated data processing using ACD Automation Server provides a reliable solution for archiving and distributing the large amounts of processed data that are generated from plate-base HTPP submissions. In addition, segmented-flow NMR methods (SFA), using a susceptibility matched push-solvent (FC-43) to limit sample dispersion in the flow cell, are also being investigated in an effort to improve S/N with mass-limited samples. The initial results of these studies, which show up to a two-fold improvement in S/N vs. single-solvent push techniques, will be presented.

Poster #21
Segmented Flow Into  LC Probes Double Flow-NMR Sensitivity and Throughput
Roger Kautz (1), David Strand (2), and Steve Hollis (3)

1.  Barnett Institute at Northeastern University, Boston, MA
2.  Protasis Corporation, Marlboro, MA
3.  Amgen Corporation, Cambridge, MA

* Maintains uniform original concentration, for ligand-binding or qNMR studies.
* Confines sample in NMR coil volume, for optimal sensitivity.
* Improves throughput by 10 min/sample; reduces solvent consumption 5-fold.
* Applicable to cryo-flow for trace sensitivity, or old LC probe for high-throughput.

Flow-injection NMR (FIA-NMR) has proven valuable for acquiring spectra directly from vials or 96-well plates, avoiding the time and expense of preparing samples in tubes, and specialized automation to load tubes. Extending our previous work in segmented flow loading of microcoil probes (“microdroplet NMR”) [1], we here show how segmented flow (SFA) loading solves several problems seen with conventional flow-NMR into LC probes (60 uL or larger).

Segmented flow loads samples without dispersion or dilution — the sample is transported like a drop of water in oil. The flow system is filled with an immiscible fluid (fluorocarbon FC43) so the sample moves as a droplet or, in narrow tubing, as an elongated plug with a sharp boundary and with uniform (undiluted) concentration throughout. FC43 has magnetic susceptibility matched to D2O, and functions as “Shigemi tubes for a flow system” to confine the entire sample within the observed volume. To implement segmented flow, use of a fluorinated fluid in Teflon tubing is ideal; fluoro-silanized glass surfaces also work well. The data presented were obtained by using a stock commercial flow-NMR platform (Protasis One-Minute NMR) with a Teflon sample loop and transfer line. SFA and FIA were compared in in video of injected dye, and in on-flow and stopped-flow NMR spectra of a standard (20 mg/mL caffeine in D2O).

Results: SFA loading was explored in a cryo-flow system with a 60 uL nominal NMR observed volume (120 uL flowcell volume; 150 uL dead vol to center of V-obs). SFA loading 70 uL of the standard gave twice (2x) the NMR signal intensity as FIA loading; which was 95% the signal intensity of a flowcell filled with the standard. A 50 uL sample could be shimmed to the same lineshape as 70 uL or larger, but accordingly shows only 70% of the signal strength (50 uL/70 uL = 71%). Video of dye injections by SFA and FIA provide a concrete picture. Samples loaded with SFA move into the detected volume as a discrete object, like a car into a garage; accordingly, on-flow NMR signal strength rises linearly from first light to 100% as the leading edge of sample fills the coil volume; plateaus at 100% while the coil is filled, then linearly decreases to 0 as the trailing boundary of the sample passes out of the detector region. FIA samples, in contrast, arrive like the hot water at a distant tap: signal intensity increases more slowly with a slope projecting to 100% after 0.7 dead volumes, but cresting and tailing for smaller samples. Parabolic flow in the flowcell produced large concentration gradients both radially and axially, reflected in the lineshape (30 Hz) of the caffeine methyl resonances, which are concentration-sensitive. When flushing samples, the tailing in FIA required 300 uL (nearly 3 flowcell volumes) to bring residual signal below 2%.

Applications: Loading samples at a defined and uniform concentration enables ligand-binding or qNMR studies. Confining samples into the observed volume gives the theoretical optimum sensitivity for a probe, under unattended automation. SFA-NMR with cryoprobes gives high sensitivity; an old LC probe would serve for high throughput of routine chemistry samples.

1.  Lin et al, Anal. Chem 80: 8045 (2008)

SMASH 2012 program:  http://www.smashnmr.org/images/previous_smash/SMASH2012/smashProgram.pdf

plci11
/by David Strand

ENC2014

image006-500x500
/by David Strand

OAHT

plci11
/by David Strand

ENC2014

image006-500x500
/by David Strand

OAHT

plci11
/by David Strand

ENC2014

image006-500x500
/by David Strand

OAHT

plci11
/by David Strand

ENC2014

Click here to add your own text