Your shopping cart is empty!
Two major development areas in HPLC-NMR hyphenation are postcolumn solid-phase extraction (HPLC-SPE-NMR) and capillary separations with NMR detection by means of solenoidal microcoils (CapNMR)....
UNC-Hamner Metabolomics UW-Medicine
Dr Tom O'Connell - Uploaded on Feb 3, 2012 In this 1-hour e-seminar Dr. Tom O'Connell (Assoc. Prof. in the Division of Pharmacotherapy and Experimental Therapeutics at the Univ. of North...
Protasis MRM overcomes the limitations of traditional NMR with its new Indirect Carbon Gradient MicroFlow NMR Probe. The CapNMR ICG probe significantly enhances NMR mass sensitivity while providing superior fluidic performance in a scant 2.5 uL of observable sample volume.
Typical homonuclear and heteronuclear NMR spectra are now possible using 100 nmol or less of analyte. The addit..
|
At SMASH 2012, Protasis introduced, CryoFlow NMR, an exciting new way to load flowcell inserts for Bruker and Agilent cryogenically-cooled probes. In this work, we were able to clearly show the advantages of both native (same push solvent as the sample) and segmented flow (for 30uL active volume) flow inserts using a Bruker CryoFit flowcell. Many pharma companies and university research gr..
|
At SMASH 2012, Protasis introduced, CryoFlow NMR, an exciting new way to load flowcell inserts for Bruker and Agilent cryogenically-cooled probes. In this work, we were able to clearly show the advantages of both native (same push solvent as the sample) and segmented flow (for 30uL active volume) flow inserts using a Bruker CryoFit flowcell. Many pharma companies and university research..
|
For Immediate Release
January 29, 2007
Protasis Confirms New Molecules for Drug Discovery
New Product Helps Synthesis Chemists in Pharmaceutical Companies Answer the Critical Question, “Did I Make What I Thought I Made?”
Protasis Corporation (Marlboro, MA, www.protasis.com) announces the release of its new Discovery High Throughput Structure Confirmation (HTSC) NMR Workstation, an au..
|
The One Minute-NMR™ automation system is the Protasis flagship offering for open-access, high-throughput sample loading of microvial-based and wellplate-based samples into the Protasis CapNMR probe. This automation system has been designed from the ground up based upon feature requests and user preferences vocalized by our pharmaceutical customers. The list of product features ..
|
Before each installation:
Ask for your magnet serial number and run through our pre-installation checklist.
Get vendor drawings and create a bracket precisely engineered your magnet internals.
Certify probe performance to factory specifications at the UIUC NMR facility.
We'll schedule a convenient time and fly out to your laboratory to reinstall your new CapNMR probe.
Mo..
|
Protasis certifies every CapNMR Probe at the University of Illinois (where microcoil NMR was invented). We can lease magnet time from 300 MHz to 600 MHz there on a variety of NMR systems. We then travel to each customer laboratory to carefully install each probe (e.g., find the 'sweet spot'), optimize it for its new magnet (e.g., tuning and shimming). We re-certify t..
|
Uptime Support Plan - Silver Level
Features:
Telephone Support
We’re available to help you and your staff. One year of unlimited access by telephone to our application and design team. Consider the the value to you – protection of the resource in shortest supply - your valuable time!
Includes:
Assistance in maintaining peak probe performance
Diagnostic assistance